This
paper describes partial discharge (PD) characteristics for on-site measurement
based on rise time waveform. The frequency of partial discharges (PD) is a
significant factor concerning electrical insulation. The implications of this
kind of PD characteristics are becoming increasingly important with the rapid
development of the detection of PD signals in medium voltage. The rise times
characteristics are used in insulation condition monitoring to keep getting
earlier information about the insulation condition of the high voltage or
medium voltage equipment. Currently, there is minimal research working on the
characteristics especially rise time and due to this, it needs to further
develop comprehensive characteristics of PD detection at such extreme conditions.
An on-site PD measurement using Rogowski coil (RC) and MATLAB analysis focusing
on rise times is presented here. Measurement was set up based on the IEC60270
standard and the circuit in the standard is followed. Insulation used in this
work is XLPE type under 11 kV voltage stress and there were eight locations
were performed in order to get a clear picture of the pattern. The overall
result indicates that the rise times range is between 1.5 and 5 ns. The impact
of rise time characteristics on the PD signal based on the real measurement is
huge since the maintenance unit can perform measurement in a short time compare
to the previous method. Specifically, the total number of PD measurement and
severity range were shown with cable length. The rise time pattern always
provide different value depending on level severity and frequency. However,
when combining the result rise time from 8 substations measured, it provides a
significant result. The finding is valuable for future PD measurement and
detection at the site when the operator directly focuses on the range value to
identify PD signals.
Author(s) Details:
Abdullah A. Z.,
Faculty of Electrical Engineering and Technology, UniMAP, Arau,
Perlis, Malaysia and Center of Excellent for Renewable Energy, UniMAP, Arau,
Perlis, Malaysia.
Isa
M.,
Faculty
of Electrical Engineering and Technology, UniMAP, Arau, Perlis, Malaysia and
Center of Excellent for Renewable Energy, UniMAP, Arau, Perlis, Malaysia.
Amlus M. H.,
Faculty of Electrical Engineering and Technology, UniMAP, Arau,
Perlis, Malaysia and Center of Excellent for Renewable Energy, UniMAP, Arau,
Perlis, Malaysia.
Azizan N.,
Faculty of Electrical Engineering and Technology, UniMAP, Arau,
Perlis, Malaysia and Center of Excellent for Renewable Energy, UniMAP, Arau,
Perlis, Malaysia.
Bakar M. F.,
Leader
Cable Industry Berhad, Tikam Batu, Sg Petani, Kedah, Malaysia.
Meor
A. Z.,
Jabatan
Kejuruteraan Elektrik, POLIMAS, Jitra, Kedah, Malaysia.
Please see the link here: https://stm.bookpi.org/TAER-V6/article/view/13370