The permeable volume and trans-membrane
pressure difference of all 3520 days, from October 2011 to November 2021, in an
A2/O-MBR RWTP (recycled water treatment plant) in Xi'an Siyuan University have
been indiscriminately used to study an evaluation method of MBR hollow fiber
membrane. The 1 m³permeable volume of 1000 ㎡membrane area
at 1 day and 1 kPa trans-membrane pressure (TMP) difference is defined as one
industrial permeability, 1 VMD. The VMD
of every day is directly calculated by using the daily computer’s records of
the RWTP. After excluding some anomalies
from the original data, an arithmetic average of each 25 days (as a group unit)
effective VMD was calculated. Then, group
units are reduced into annual units.
After four years, a power equation is fitted into the annual VMD
attenuation equation of the previous four years of RWTP operation. The calculation of the annual VMD attenuation
equation is straightforward, simple, and convenient. The VMD declined annually by about 0.78. The TMP increased annually by about 0.66 kPa.
Author(s) Details:-
Li
Dong
Energy and Chemical Engineering Research Center,
Xi' an Siyuan University, Xi'an 710038, China.
Zhang
Xuemei
Energy and Chemical Engineering Research Center,
Xi' an Siyuan University, Xi'an 710038, China.
Ma
Qinghua
Energy and Chemical Engineering Research Center,
Xi' an Siyuan University, Xi'an 710038, China
Fu
Bo
Regenerative Water Plant, Xi 'an Siyuan University,
Xi' an 710038, China.
Qin
Baolan
Regenerative Water Plant, Xi 'an Siyuan University,
Xi' an 710038, China.
Hao
Jingyuan
Energy and Chemical Engineering Research Center,
Xi' an Siyuan University, Xi'an 710038, China and School of Chemical
Engineering and Technology, No. 28, Xianning West Road, Beilin District, Xi’an
710048, China.
Please see the link here: https://doi.org/10.9734/bpi/caert/v2/8441E
No comments:
Post a Comment