Showing posts with label respiratory rate. Show all posts
Showing posts with label respiratory rate. Show all posts

Friday, 7 May 2021

Effect of Protective Coats on Physiological Parameters of Angora Kids Exposed to Cold, Wet and Windy Conditions: An Advanced Study | Chapter 1 | Cutting-edge Research in Agricultural Sciences Vol. 8

 In Angora goat kids exposed to cold, wet, and windy conditions, protective coats were tested on rectal, skin, and subcutaneous temperature, heart rate, respiratory rate, shivering score, and serum glucose level. In 2009, the experiment was conducted on 24 ten-month-old castrated male Angora goat kids and 30 nine-month-old castrated male Angora goat kids at the Grootfontein Agricultural Development Institute. During the 2009 and 2010 cold stress trials, the rectal temperature of animals in both the Coats and Control groups decreased. At the end of the trial in 2009, the Coats group's rectal temperature was 1.91°C higher (36.49 0.45) than the Control group's (34.58 0.45). The animals in the Coats group had a 2.21°C lower rectal temperature drop than the Control group. In 2010, a similar pattern was found, but the Coats group animals' rectal temperature was only 0.87°C higher than the Control group's.

There were also variations in skin temperature between the two classes. The most noticeable difference between skin temperatures measured on the shoulder and britch; the area directly covered by the coats; was measured on the shoulder and britch. The animals covered by coats had slightly lower daily temperature amplitudes than the Control group animals during the early days of the 2010 study, when the animals were freshly shorn. As hair length increased, the variations in regular amplitude between the groups became less pronounced. After four weeks of hair development, there were no major variations in subcutaneous temperatures between Coats and Control group animals. For the first two hours of the experiment, animals in both the Coats and Control groups had a higher heart rate, which then dropped to below the initial values at the end. The Coats and Control groups' serum glucose levels dropped significantly towards the end of the trial period, to 1.33 ng/ml and 1.66 ng/ml, respectively. The fact that both groups of animals shivered to the same extent and had a drop in skin temperature on the extremities and periphery at the end of the trial period indicates that the coats were not fully capable of providing total protection against cold, wet, and windy conditions to the point that all of the body's thermoregulatory mechanisms were activated. The true test of whether protective coats provide sufficient protection to freshly shorn Angora goats during severe weather conditions will be performed when they are tested on a larger scale in practise under natural cold and wet weather conditions. Angora kids wearing protective coats were able to sustain higher rectal temperatures than goats without protective coats during cold, wet, and windy conditions, according to the findings of this report.

Author (s) Details

M. A. Snyman
Grootfontein Agricultural Development Institute, Private Bag X529, Middelburg (EC), 5900, South Africa.

M. van Heerden
Grootfontein Agricultural Development Institute, Private Bag X529, Middelburg (EC), 5900, South Africa.

View Book :- https://stm.bookpi.org/CRAS-V8/article/view/783

Friday, 25 September 2020

Customized Bubble Continuous Positive Airway Pressure (BCPAP) Device at the National Hospital Abuja Gives Immediate Clinical Improvement (Respiratory Rate, Grunting and Oxygenation) in Neonates with Respiratory Distress | Chapter 8 | Research Trends and Challenges in Medical Science Vol. 5

 

Background: Prematurity accounts for 25% of Neonatal mortality in Nigeria and Respiratory Distress
Syndrome is responsible for half of these deaths. Introducing continuous positive airway pressure for
the treatment of RDS in Nigeria where health care financing is predominantly out-of-pocket is quite
challenging. It was hypothesized that applying the principle of under-water-seal pressure generation
could convert a simple oxygen delivery system into an effective Bubble CPAP device the National
Hospital Abuja CPAP
Objectives: To provide evidence in support of the immediate clinical effectiveness of the NH ABCPAP device.
Design/Methods: At the neonatal unit of the National Hospital Abuja, we assembled a circuit of
tubing connecting a gas source (oxygen concentrator or cylinder) through an interface (nasal prongs)
to the baby and this was further connected through an expiratory tube to an under-water-seal bottle to
generate CPAP. The device is activated by turning on the oxygen source. The device was applied to
preterm babies with RDS as well as some term babies with respiratory distress admitted into the
neonatal intensive care units. Respiratory rate, SPO2 and other signs of respiratory distress were
monitored before and at 1 hour, 6 hours and 12 hours after the application.
Results: Forty eight newborn babies with respiratory distress were treated with the device out of
whom twenty three (48%) were very low birth weight with respiratory distress syndrome. The mean
respiratory rate dropped from 64.5 (19.2)/min before commencement of CPAP to 59.5(11.6)/min, 56.6
(10.5), and 56.6(10.7) at 1, 6 and 12 hours respectively, p<0.05. The corresponding values for SPO2
were 84.5(14) before and 95.9 (5.3), 95.9(6.5) and 96.9(6.4) at 1, 6 and 12 hours respectively,
p<0.05. The respiratory changes were however less marked among very low birth weight babies.
Conclusion: The simplified customized device produces clinical responses similar to those reported
for the conventional CPAP devices.

Author (s) Details

Dr. L. I. Audu
Department of Paediatrics and Child Health, Barau Dikko Teaching Hospital, Kaduna State University, Kaduna, Nigeria.

A. T. Otuneye
Neonatal Unit, National Hospital Abuja, Plot 132, National Hospital Road, Central Business District, P.M.B. 425, Abuja, Nigeria.

Dr. A. B. Mairami
Neonatal Unit, National Hospital Abuja, Plot 132, National Hospital Road, Central Business District, P.M.B. 425, Abuja, Nigeria.

M. Mukhtar- Yola
Neonatal Unit, National Hospital Abuja, Plot 132, National Hospital Road, Central Business District, P.M.B. 425, Abuja, Nigeria.

View Book :- https://bp.bookpi.org/index.php/bpi/catalog/book/264