Showing posts with label pyridoxine hydrochloride. Show all posts
Showing posts with label pyridoxine hydrochloride. Show all posts

Thursday, 2 November 2023

HPLC Methods for the Quantification of Cyproheptadine Hydrochloride, Vitamins Using RP-HPLC with UV Detection | Chapter 6 | Advanced Concepts in Pharmaceutical Research Vol. 2

 For the purposes concerning this investigation, we have forged straightforward RP-HPLC methods for the analysis of cyproheptadine hydrochloride, thiamine mononitrate, calcium pantothenate, and pyridoxine hydrochloride. The International Conference on Harmonization's (ICH) Q2(R1) 2005 tests were followed in the conduct concerning this study. The quality control of various APIs in single dose forms depends massively on the availability of reliable, high-throughput examining technologies. Here, we present the growth and validation of two methods for the identification and calculation of calcium pantothenate, cyproheptadine hydrochloride (CH), thiamine mononitrate (Vit. B1), and pyridoxine hydrochloride (Vit. B6) in uncoated tablets. For the vitamin test, a movable phase combination of phosphate buffer pH 3.5 and flammable liquid in the ratio 93:7 was secondhand. The stationary point used was Eurospher ODS (150 x 4.5mm), and the flow rate was judge 1.0 mL/min (ambient hotness settings). For thiamine mononitrate and pyridoxine hydrochloride, the awareness of detection was 270 nm accompanying a run time of 0.00 to 5.50 summary, and for calcium pantothenate, it was 205 nm with a run occasion of 5.50 to 11.00 minutes. The dose volume was 20 µL. A good judgment, and a short run time of 11 record were achieved accompanying the validated environments. The retention opportunities of thiamine mononitrate, pyridoxine hydrochloride and calcium pantothenate were 2.823 ± 0.020, 4.184 ± 0.007 and 10.025 ± 0.015 minutes individually.The mobile phase arrangement for cyproheptadine HCl was methanol and an ion-making solution (70:30), judge a flow rate of 1.0 mL/min, a runtime of 8 notes of meeting, an injection capacity of 20 µL, and a wavelength of 285 nm utilizing Eurospher ODS (150 x 4.5 mm) as the stationary chapter. The retention opportunity for cyproheptadine HCl was 4.961 ± 0.006.Both methods were raise to be distinguishing, with undeviating dynamic ranges of 0.0192 mg/mL - 0.0288 mg/mL for thiamine mononitrate, 0.0128 - 0.0192 mg/mL for pyridoxine hydrochloride, 0.032 - 0.048 mg/mL for calcium pantothenate and 0.032 - 0.048 mg/mL for cyproheptadine hydrochloride. The equivalence coefficient (R2) for cyproheptadine hydrochloride, thiamine mononitrate, pyridoxine hydrochloride and calcium pantothenate were more 0.999.The purpose of this study was to evolve and validate plain HPLC methods for the belief of cyproheptadine hydrochloride, vitamins B1, B5 and B6 in combined portion of drug or other consumable forms. The proposed means were found expected precise, correct, and robust for the belief of cyproheptadine hydrochloride, vitamins B1, B5 and B6.

Author(s) Details:

Yayra Tuani,
Letap Pharmaceuticals Ltd., P.O. Box GP 3346, Accra, Ghana.

Seth Amo-Koi,
United States Pharmacopeia-Ghana, No. 3 Park Avenue, Motorway Extension, North Dzorwulu, P.O. Box WY 1204, Kwabenya, Accra, Ghana.

David Mingle,
Department of Pharmaceutical Sciences, College of Pharmacy, University of Tennessee Health Science Centre, 881 Madison Ave, Memphis, TN 38163, USA.

Andrew Gordon,
Department of Science Laboratory Technology, Accra Technical University, Accra, Ghana.

Angela Asor,
Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.

Please see the link here: https://stm.bookpi.org/ACPR-V2/article/view/12338

Friday, 20 May 2022

Assessment of Isoniazid and Pyridoxine Hydrochloride in Pure and Pharmaceutical Preparations| Chapter 11 | Progress in Chemical Science Research Vol. 1

For the simultaneous assay of pyridoxine hydrochloride and isoniazid, a new spectrophotometric approach was devised. The approach was based on a proton transfer reaction between pyridoxine hydrochloride B6 and chromeazurol S at pH = 5.7, which produced a red, water soluble compound that absorbed at 510 nm. This technique for detecting isoniazid IND was discovered by bleaching the red-colored product, pyridoxine hydrochloride –chromeazurol S. Numbness and elevated blood levels of liver enzymes are frequent adverse effects of the IND. At concentrations ranging from 5 to 700 g/25ml for pyridoxine hydrochloride (i.e. 0.2-28.0) ppm, the molar absorptivity value was 1.51104 l/mol.cm, while at concentrations ranging from 25 to 1500 g/25ml for isoniazid (i.e. 1-60) ppm, the value of molar absorptivity was 1.36104 l/ This research seeks to develop a spectroscopic technique for determining isoniazid and pyridoxine hydrochloride in pharmaceutical formulations. As a result, this method has been successfully employed to detect pyridoxine hydrochloride and isoniazid in pharmaceutical formulations.

Author(s) Details:

Basima A. A. Saleem,
Department of Chemistry, College of Science, Mosul University, Mosul, Iraq.

Please see the link here: https://stm.bookpi.org/PCSR-V1/article/view/6769